1. Safety Precautions

To ensure that users use this product safely and correctly and to avoid injury to personnel, the following safety precautions are hereby established. Before using this product, be sure to carefully read the following safety precautions:

(1)The suitability of this product should be judged by the system designer or specification creator. The usage conditions of this product are diverse; please have the system designer or specification creator judge the suitability of the system. If necessary, make the judgment through analysis and testing. Please build the system on the basis of referring to the latest product information, confirming the entire content of the specifications, and taking possible failures into consideration.

(2)Please have personnel with sufficient knowledge and experience use this product. Improper operation of the product described herein can impair its safety. Work such as assembly, operation, and maintenance of mechanical equipment should be performed by persons with sufficient knowledge and experience.

(3)Be sure to confirm the safety of the machinery and equipment before using or disassembling the product.

  1. Please use and maintain the machinery and equipment only after confirming that fall-prevention measures for moving parts and runaway-prevention measures have been implemented.

  2. Please disassemble the product while confirming that the above safety measures have been taken and that the energy source and equipment power supply have been cut off to ensure system safety, and on the basis of confirming and understanding the individual precautions for the product on the equipment.

  3. When restarting machinery and equipment, please take preventive measures against unexpected motion and erroneous operation.

(4)When using the product under the conditions and environments shown below, please consult our company in advance while also considering safety measures.

  1. Conditions or environments other than the explicitly stated specifications.

  2. Use in applications such as nuclear power, railways, aviation, space equipment, ships, military, medical equipment, food equipment, fuel devices, safety equipment, etc., as well as use in applications involving standard specifications not described in the product manual.

  3. Use where a significant impact on personal safety and property is anticipated, especially in applications with safety requirements.

  4. When used in interlock circuits, please provide mechanical protection functions against failures to achieve double interlocking. In addition, perform periodic inspections to confirm normal operation.

2. General Introduction

As the scale of the robot market continues to expand, the demand for robot joints across various industries has grown accordingly, prompting companies to develop more universal, high-performance joint products to meet the diverse needs of the market, reduce production costs, and enhance market competitiveness.

Some domestic peer companies’ joint products have been widely used in industrial robots and collaborative robots, meeting the requirements of application scenarios, with emphasis on product load capacity and reliability. The company already has mature joints for collaborative robots and has also developed joints for humanoid robots. Based on existing technical reserves, the development of general-purpose joints featuring small size, light weight, high quality, and low cost will be firmly centered on solving customer problems and delivering value, in order to build its own product domain and blue ocean.

3. Basic Product Information

3.1. FM-11-B Basic Information

Parameter Type

Parameter Breakdown

Product Type

FM-11-B

Product Weight/g

420

Dimensions/mm

φ52*68.5

Reduction Ratio

100

Rated Torque/N.m

3.7

Average Load Torque/N.m

6.2

Maximum Torque/N.m

17.5

Rated Speed/RPM

30

Repeat Positioning Accuracy/”

±15

Central Bore Diameter/mm

10

Operating Temperature/℃

0~45℃

Rated Power/W

31

Rated Voltage/V

48

Brake

Supported

Communication Interface

EtherCAT

3.2. FM-14-B Basic Information

Parameter Type

Parameter Breakdown

Model

FM-14-B

Product Weight/g

730

Dimensions/mm

φ70*83.6

Reduction Ratio

100

Rated Torque/N.m

9

Average Load Torque/N.m

13

Maximum Torque/N.m

63

Rated Speed/RPM

30

Repeat Positioning Accuracy/”

±15

Central Bore Diameter/mm

12

Operating Temperature/℃

0~45℃

Rated Power/W

100

Rated Voltage/V

48

Brake

Supported

Communication Interface

EtherCAT

3.3. FM-17-B Basic Information

Parameter Type

Parameter Breakdown

Model

FM-17-B

Product Weight/g

1054

Dimensions/mm

φ80*97.4

Reduction Ratio

120

Rated Torque/N.m

24

Average Load Torque/N.m

39

Maximum Torque/N.m

86

Rated Speed/RPM

25

Repeat Positioning Accuracy/”

±15

Central Bore Diameter/mm

12

Operating Temperature/℃

0~45℃

Rated Power/W

200

Rated Voltage/V

48

Brake

Supported

Communication Interface

EtherCAT

4. Product Overall Dimensions and Mounting Hole Positions

4.1. FM-11-B Overall Dimensions and Mounting Hole Positions

001.png

Figure 4-1 FM-11-B Overall Dimensions and Mounting Hole Positions

4.2. FM-14-B Overall Dimensions and Mounting Hole Positions

002.png

Figure 4-2 FM-14-B Overall Dimensions and Mounting Hole Positions

4.3. FM-17-B Overall Dimensions and Mounting Hole Positions

003.png

Figure 4-2 FM-17-B Overall Dimensions and Mounting Hole Positions

5. Installation Notes

Before installation, please carefully read the safety instructions related to the universal joint (1.1 Safety Precautions). Do not turn on the power before the product is secured in place.

5.1. Operating Conditions

The operating, transportation, and storage conditions of the universal joint are:

  1. Operating ambient temperature: 0℃~+45℃;

  2. Operating ambient humidity: 20%~90% RH (40°C) (no frost and no condensation);

  3. Transportation and storage temperature: -20℃ ~ +60℃ (no frost and no condensation);

Warning

Universal joints must be kept away from environments with vibration and impact; the environment must be free of dust, smoke, or water, free of corrosive gases, liquids, or explosive gases, and free of strong electromagnetic interference sources.

5.2. Electrical Interface

Schematic diagram of the electrical interface of each universal joint:

(1)FM-11-B joint electrical interface diagram:

004.png

Figure 5-1 FM-11-B Joint Electrical Interface Diagram

(2)FM-14/17-B joint electrical interface diagram:

005.png

Figure 5-2 FM-14/17-B Joint Electrical Interface Diagram

5.3. Cable Connection

Power and Debug Harness Connector Model:

(1)Power Harness

006.png

Figure 5-3-1 Power Harness

(2)Network Cable Harness

061.png

Figure 5-3-2 Network Cable Harness

(3)Debug Harness

The debug harness is a harness exclusively supplied by Fairino and can be purchased as needed.

062.png

Figure 5-3-3 Debug Harness

6. Parameter Adjustment

6.1. Basic Settings

007.png

Figure 6-1 Basic Parameter Function Description Table

6.2. Communication Parameters

008.png

Figure 6-2 Communication Parameters Function Description Table

009.png

Figure 6-3 Communication Interface Function Description Table

010.png

Figure 6-4 Baud Rate Function Description Table

6.3. Motor Parameters

Motor parameter items: total length 60 elements, element type S32, currently valid data is elements 2-21; all valid elements are readable and writable.

011.png

Figure 6-5 Motor Parameters Function Description Table

012.png

Figure 6-6 Encoder Type Function Description Table

6.4. Drive Parameters

Monitoring parameter items: total length 60 elements, element type S32, currently valid data is elements 2-11; all valid elements are readable and writable.

013.png

Figure 6-7 Drive Parameters Function Description Table

6.5. Monitoring Parameters

Monitoring parameter items: total length 60 elements, element type S32, currently valid data is elements 2-8; valid elements are read-only and do not support writing. For detailed fault code descriptions, see the Alarm Code Table.

014.png

Figure 6-8 Monitoring Parameters Function Description Table

6.6. Parameter Adjustment

Adjustment parameter items: total length 60 elements, element type S32, currently valid data is elements 2-32; all valid elements are readable and writable.

015.png

Figure 6-9 Adjustment Parameters Function Description Table

6.7. Motion Control

Motion control parameter items: total length 60 elements, element type S32, currently valid data is elements 0-27; all valid elements are readable and writable.

  • 3 - Motor forward rotation direction: 0 - runs in CCW direction, 1 - runs in CW direction.

  • 16 - Internal speed command speed 1: valid in PV mode; PV mode speed command.

016.png

Figure 6-10 Motion Control Function Description Table

6.8. Protection Parameters

Protection parameter items: total length 60 elements, element type S32, currently valid data is elements 2-19; all valid elements are readable and writable.

  • 15 - Fault reset parameter: when set, executes the fault reset function for resettable faults and warnings;

017.png

Figure 6-11 Protection Parameters Function Description Table

6.9. Auxiliary Functions

Auxiliary parameter items: total length 60 elements, element type S32, currently valid data is elements 2-30; all valid elements are readable and writable.

  • 14 - Braking voltage of the energy-consumption resistor: default parameter 51000Mv; maximum energy-consumption braking voltage 70000Mv.

  • 11~13 Electromagnetic brake voltage: default parameter 24000Mv; maximum supported brake voltage 48000Mv

018.png

Figure 6-12 Auxiliary Parameters Function Description Table

6.10. Limit Parameters

Limit parameter items: total length 60 elements, element type S32, currently valid data is elements 2-16; all valid elements are readable and writable.

  • 13 - Motor forward position range parameter: valid for multi-turn encoders; this parameter is the forward motion range of the multi-turn encoder. For example, if the multi-turn encoder is 0~65535, it is recommended to set the forward range to 32767, approximately half the multi-turn encoder resolution.

The 360° rotation support function is disabled by default; to enable it, configure parameters 13~15 and set parameter 16 (360° rotation support) to 1.

If the motor forward position range parameter is greater than the single-turn encoder resolution, the forward motion range is (multi-turn encoder resolution * single-turn encoder resolution = total encoder resolution)/2.

019.png

Figure 6-13 Limit Parameters Function Description Table

6.11. Input/Output 1

Input/Output 1 parameter items: total length 60 elements, element type S32, currently valid data is elements 0-12. 3 - Lower four input terminal parameters: set - motor enable; reset - motor disable. (The communication interface in the communication parameters must be set to 0 (debug 485) before enable and disable can take effect by setting all parameters.)

020.png

Figure 6-14 Input/Output 1 Parameters Function Description Table

6.12. Input/Output 2

Input/Output 2 parameter items: total length 60 elements, element type S32, currently valid data is elements 2-18.

021.png

Figure 6-15 Input/Output 2 Parameters Function Description Table

6.13. Adaptive PID Stiffness 0

Adaptive PID stiffness 0 parameter items: total length 60 elements, element type S32, currently valid data is elements 2-30.

Must be used together with the closed-loop PID mode parameter items to switch between adaptive PID and feedforward control modes.

022.png

Figure 6-16 Adaptive PID Stiffness 0 Parameters Function Description Table

6.14. Adaptive PID Stiffness 1

Adaptive PID stiffness 1 parameter items: total length 60 elements, element type S32, currently valid data is elements 2-30.

Must be used together with the closed-loop PID mode parameter items to switch between adaptive PID and feedforward control modes.

023.png

Figure 6-17 Adaptive PID Stiffness 1 Parameters Function Description Table

6.15. Adaptive PID Stiffness 2

Adaptive PID stiffness 2 parameter items: total length 60 elements, element type S32, currently valid data is elements 2-30.

Must be used together with the closed-loop PID mode parameter items to switch between adaptive PID and feedforward control modes.

024.png

Figure 6-18 Adaptive PID Stiffness 2 Parameters Function Description Table

6.16. Closed-Loop Feedforward Control

Closed-loop feedforward control parameter items: total length 60 elements, element type S32, currently valid data is elements 2-30.

Must be used together with the closed-loop PID mode parameter items to switch between adaptive PID and feedforward control modes.

025.png

Figure 6-19 Closed-Loop Feedforward Control Parameters Function Description Table

6.17. Closed-Loop PID Mode

Closed-loop control mode parameter items: total length 60 elements, element type S32, currently valid data is elements 2-3.

  • 2 - Closed-loop control mode: 0: select closed-loop feedforward control; 1: select adaptive PID control

  • 3 - Adaptive PID stiffness: when the closed-loop control mode is PID adaptive control, stiffness configuration and control can be performed.

026.png

Figure 6-20 Closed-Loop PID Mode Parameters Function Description Table

027.png

Figure 6-21 Closed-Loop Control Mode Parameters Function Description Table

028.png

Figure 6-22 Adaptive PID Stiffness Parameters Function Description Table

7. Host Computer Debugging Software DynamicLAB

7.1. Establishing a Connection

  1. Select the device (drive) to be connected in the device list;

  2. Select the correct COM port;

  3. Set the communication baud rate (default 115200);

  4. Click Address Scan to automatically scan the number and addresses of slave stations on the main line;

  5. Click Connect to communicate with the slave station.

029.png

Figure 7-1 Device List and Communication Settings Diagram

  1. Displays that the serial port was opened successfully;

  2. Displays that the underlying motor parameters were obtained successfully;

Indicates that the connection with the drive was established successfully.

030.png

Figure 7-2 Connection Function Diagram

7.2. Firmware Upgrade

485 Upgrade:

  1. Select Firmware Upgrade in the function tree;

  2. Select the upgrade method (default: 485 upgrade);

  3. Open the firmware file (.bin) to be upgraded;

  4. Send the file to start file transfer;

  5. Wait for the message bar to display that the file has been sent successfully;

031.png

Figure 7-3 Firmware Upgrade Diagram

JLink Upgrade:

  1. Select Firmware Upgrade in the function tree;

  2. Select the upgrade mode and select JLink upgrade (requires installing the JLink driver; use a USB-to-JLink tool to connect the computer and the drive);

  3. Click JLink Connect to connect to the drive;

  4. Flash Erase is used to erase the firmware program in the drive;

  5. Open the file and select the firmware program to be upgraded (.hex format file);

  6. Click Send File to perform the firmware upgrade.

7.3. Parameter List

032.png

Figure 7-4 Firmware JLink Upgrade Diagram

  1. Select Parameter List in the function tree;

  2. Parameters are divided into sub-parameters according to their functions;

  3. For parameters: Load (load from file), Save (save parameters as a file), Read (read parameters from the drive), Write (write parameters to the drive; on each sub-parameter page, Read and Write apply only to the current sub-parameter, while in the parameter list, Read and Write apply to all parameters), Write FLASH (write parameters to FLASH), Restore Factory Settings (restore the drive parameters to factory defaults);

  4. Double-click to modify a parameter value (must be written after modification);

033.png

Figure 7-5 Parameter List Diagram

7.4. Full Parameter Configuration

  1. Select Parameter List in the function tree and click Load.

034.png

Figure 7-6 Function Tree Parameter List

  1. Select the full parameter configuration file for the corresponding joint in the DynamicLAB folder

035.png

Figure 7-7 Full Parameter Configuration File

  1. When the prompt window indicates “All parameters loaded”, click “Write”; after the prompt indicates a successful write, click “Write Flash” to complete writing to Flash, then power off and power on again, and perform a Read operation to check whether the write was successful.

036.png

Figure 7-8 Write to Flash

7.5. Running in Speed Mode

  1. In Parameter List - Communication Parameters, switch the communication interface to 0 (debug 485 interface) and perform the write operation.

037.png

Figure 7-9 Switch to 0 and Write

  1. In Parameter List - Motion Control, switch the control mode to 1 (speed mode) and perform the write operation.

038.png

Figure 7-10 Switch to 1 and Write

  1. In Parameter List - Input/Output 1, write 1 to the control word that forces the lower four input terminals ON, and perform the write operation. The motor is enabled.

039.png

Figure 7-11 Write 1 to the Control Word

  1. In Parameter List - Motion Control, issue internal speed command speed 1 and perform the write operation; the motor starts running at the set speed.

040.png

Figure 7-12 Write Command Speed 1

8. Communication Protocol

8.1. EtherCAT Communication

EtherCAT, short for Ethernet for Control Automation Technology, was developed by Beckhoff Automation GmbH and is a real-time Ethernet used for open network communication between masters and slaves. As a mature industrial Ethernet technology, EtherCAT features high performance, low cost, and ease of use.

041.png

Figure 8-1 EtherCAT Communication Specification Table

Note

Click Run Control to use the standard CiA402 profile.

8.2. EtherCAT Object Dictionary

8.2.1. PDO Object Dictionary

The PDO object dictionary is divided into RxPDO and TxPDO. RxPDO is used by the drive to receive data from the master, and TxPDO is used by the drive to feed data back to the master.

8.2.2. RxPDO

  1. Control Word object dictionary, readable and writable (RW), index 0x6040, sub-index 0, data type unsigned 16-bit. Each bit of the control word is described below.

042.png

Figure 8-2 Control Word Object Dictionary Details

Among them, bit3-bit0 (enable operation/quick stop/enable voltage/switch on) comply with the CiA402 protocol standard, as shown in the figure below.

043.png

Figure 8-2 CiA402

The joint can be enabled and disabled through the control word. To enable it, assign the control word in sequence (0x06->0x07->0x0F); to disable it, assign 0 directly to the control word.

Robot zero calibration can be performed through the control word. When the joint is disabled and not in the OP state, set bit13 of the control word to 1.

  1. Target Position object dictionary, readable and writable (RW), index 0x607A, sub-index 0, data type signed 32-bit.

044.png

Figure 8-3 Target Position Object Dictionary

Update the required target position through this object dictionary; the unit is pulse. The difference between two consecutive 607Ah target position values planned by the host computer must be less than 100000 pulses.

  1. Target Torque object dictionary, readable and writable (RW), index 0x6071, sub-index 0, data type signed 16-bit.

045.png

Figure 8-4 Target Torque Object Dictionary

Update the required target torque through this object dictionary; the unit is 0.1% of rated torque.

  1. Velocity Feedforward (Velocity offset) object dictionary, readable and writable (RW), index 0x60B1, sub-index 0, data type signed 32-bit.

046.png

Figure 8-5 Velocity Feedforward Object Dictionary

Set a reasonable velocity feedforward through this object dictionary.

  1. The remaining RxPDO object dictionaries (0x2001, 0x2010, 0x2011, 0x2012, and 0x2013) are not actually used and are not described here.

8.2.3. TxPDO

  1. Status Word object dictionary, read-only (RO), index 0x6041, sub-index 0, data type unsigned 16-bit. Each bit of the status word is described below.

047.png

Figure 8-6 Status Word Object Dictionary Details

First, the state of the power state machine can be determined by the combination of bit6, 5, 3-0 (switch on disabled/quick stop/fault/operation enabled/switched on/ready to switch on), as detailed in the figure below.

048.png

Figure 8-7 Power State Machine State Confirmation Table

  • bit13 (home): when 1, indicates that zero calibration has been completed.

  • bit12 (drag): when 1, indicates entry into drag mode.

  • bit5 (quick stop): when 0, indicates that the power state machine has received a quick stop request.

  • bit4 (voltage enabled): when 1, indicates that the main circuit power supply voltage is applied to the main circuit.

  1. Position Actual Value object dictionary, read-only (RO), index 0x6064, sub-index 0, data type signed 32-bit.

049.png

Figure 8-8 Current Position Object Dictionary

Obtain the current position data of the joint through this object dictionary; the unit is pulse.

  1. Error Code object dictionary, read-only (RO), index 0x603F, sub-index 0, data type unsigned 16-bit.

050.png

Figure 8-9 Error Code Object Dictionary

If this object dictionary is not 0, the drive has a fault.

  1. Torque Actual Value object dictionary, read-only (RO), index 0x6077, sub-index 0, data type signed 16-bit.

051.png

Figure 8-10 Real-Time Torque Object Dictionary

Obtain the real-time torque data of the joint through this object dictionary; the unit is 0.1% of rated torque.

  1. Velocity Actual Value object dictionary, read-only (RO), index 0x606C, sub-index 0, data type signed 32-bit.

052.png

Figure 8-11 Real-Time Velocity Object Dictionary

Obtain the real-time velocity data of the joint through this object dictionary; the unit is rpm.

  1. The remaining TxPDO object dictionaries (0x2000, 0x3010, 0x3011, 0x3012, and 0x3013) are not actually used and are not described here.

8.2.4. SDO

When the master sets the slave’s SDO object dictionary, it is recommended that the motor be in the disabled state; otherwise, abnormal warnings may occur. When reading, there is no need to be concerned about the motor state. 1. Software Version object dictionary, read-only (RO), index 0x100A, sub-index 0, data type visible string.

053.png

Figure 8-12 Software Version Object Dictionary

During power-on initialization, the drive firmware assigns the firmware version number to this object dictionary; the current firmware version number of the drive can be viewed through this object dictionary.

  1. Basic Settings (sBaseSetPara), Communication Parameters (sCommPara) object dictionary, Drive Parameters (sDrivePara) object dictionary, Monitoring Parameters (sDisplyPara) object dictionary, Adjustment Parameters (sAdjPara) object dictionary, Motion Control (sMtCtrlPara) object dictionary, Protection Parameters (sKeepPara) object dictionary, Auxiliary Functions (sAuxPara) object dictionary, Limit Parameters (sLmtPara) object dictionary, Input/Output 1 (sIoPara1) object dictionary, Input/Output 2 (sIoPara2) object dictionary, Adaptive PID Stiffness 0~2 object dictionary, Closed-Loop Feedforward Control object dictionary, Closed-Loop PID Mode object dictionary. For details, see Appendix 2: SDO Read/Write Drive Full Parameter Table - V0.4-20251208.

  2. Full-parameter reading and modification are performed through the parameter command at sub-index 1 of each object dictionary. Taking the Basic Settings object as an example: to modify parameters, after modifying sub-index contents such as the password and drive model, write 1 to the parameter command to write all parameters into the drive RAM; when complete, the drive sets the parameter command to 0; write 2 to the parameter command to write all parameters into the drive Flash; when complete, the drive sets the parameter command to 0. To read parameters: write 2 to the parameter command; the drive places the parameters into the Basic Settings SDO object dictionary and then sets the parameter command to 0.

054.png
055.png

Figure 8-13 Configuration Object Dictionary

9. Motor Control Mode

9.1. Position Mode

In position mode, the upper controller completes the position command planning and then sends the planned target position via 607Ah to the servo drive in a cyclically synchronized manner; position, speed, and torque control are completed inside the servo drive.

056.png

Figure 8-14 Position Operation Mode Diagram

9.2. Configuration Diagram in Position Mode

057.png

Figure 8-15 Position Mode Setting Flowchart

10. Service Life

FM universal joint average service life: 50000 h.

11. Appendix

11.1. Appendix 1 Alarm Code Table

058.png
059.png
060.png

11.2. Appendix 2: SDO Read/Write Drive Full Parameter Table - V0.4-20251208