2. Unboxing, Moving, Installation and Activation Instructions

2.1. Unboxing and Inspection

The humanoid robotic arm ART14-R7 has four configurations: Configuration one is a single arm, configuration two is a single arm + controller, configuration three is dual arms, and configuration four is dual arms + controller + distributor. As shown in 2-1, 2-2, 2-3 and 2-4. After arrival, please check the packing list to confirm the contents of the package.

004.png

Chart 2-1 configuration one single arm

005.png

Chart 2-2 configuration two single arm and controller

006.png

Chart 2-3 configuration three double arms

007.png

Chart 2-4 configuration dual arms, controllers, and splitters

2.2. Move

Note

../_images/002.png

Name:Danger

Explanation:

  • Please set up safety barriers around the robotic arm, the safety barriers should have characteristics that make them difficult to climb over or move. Otherwise, workers may enter the area while the robotic arm is in operation, leading to personnel injury and equipment damage.

  • Please clearly mark the robotic arm movement area.

Note

../_images/003.png

Name:Warning

Explanation:

  • Use of lifting equipment, forklifts, and other handling robotic arms must be carried out by personnel holding an operation qualification certificate or those permitted by the company. Otherwise, there is a possibility that the robotic arm may drop during handling, thus leading to an accident.

  • After the robotic arm is installed, ensure that when the robotic arm is fully extended, its wrist tool or workpiece tip will not touch the walls or safety barriers. Otherwise, it may cause personnel injury and equipment damage.

  • The robotic arm must be secured before connecting the power and starting it. Otherwise, there is a risk of the robotic arm toppling over, which may lead to personnel injury and equipment damage.

  • Please do not operate the robotic arm with missing or damaged parts, otherwise, the robotic arm may malfunction, causing injury to personnel and damage to equipment.

  • During the moving process, please avoid excessive vibration and impact. Otherwise, it will affect the performance of the robotic arm.

Humanoid robotic arm ART14-R7 product (including packaging) has a total weight of about 32⁓54kg, requiring multiple people to lift it, and it is not recommended for single-person operation to avoid accidents. Before long-distance transportation, please adjust the robotic arm to the specified packing posture and transport it after packaging in a dedicated carton.

2.3. Installation and Fixing

2.3.1. Ontology Installation and Fixation

Anthropomorphic robotic arm ART14-R7 base dimensions are shown as in 2-5.

There are 4 mounting holes on the base of the robotic arm, and the recommended specifications for the screws to fix the robotic arm can be found in Table 2-1.

Table 2-1 Recommended Screw Specifications for Fixing Robotic Arms

Installation

Screw specifications

Cylinder Head Screw with Hex SocketM8×30(RecommendedGB/T 3098.1 12.9Grade)

Locating pin specifications

Ø8×20

Screw tightening torque

≥42N·m

Screw quantity

4

008.png

Chart 2-5 Base Installation Dimensions

2.3.2. Controllers and distributors

The controller dimensions are 100mm×80mm×40mm, as shown in figure 2-6. The splitter dimensions are 101mm×81mm×22mm, as shown in figure 2-7.

009.png

Chart 2-6 controller appearance diagram

010.png

Chart 2-7 Branching Device Appearance Diagram

2.4. Storage location and usage environment

2.4.1. storage location

Anthropomorphic robotic arm ART14-R7 should be stored in-20~60℃, without frost conditions.

2.4.2. Usage Environment

The place for installing the robotic arm needs to meet the following conditions:

  • The robotic arm should operate within a surrounding temperature of 0°C~45°C;

  • low humidity, relatively dry(working humidity90%RH, no condensation);

  • will not be subjected to significant impact and vibration;

  • Keep away from dust, powder, metal particles, corrosive gases, flammable gases, oil mist, etc.;

  • Keep away from strong magnetic fields, keep away from sources of electrical interference, etc.;

The environmental temperature conditions are only for the applicability of the robotic arm. If you need to use it in a place that does not meet the above conditions, please consult our company.

2.5. Enable

Before the product is installed and used, the customer must conduct a comprehensive safety assessment for the specific application scenario, focusing on residual risk factors, and configure the software and hardware accordingly based on this manual. When starting the robotic arm for the first time, it is essential to closely observe its movement space to ensure there are no interferences or obstacles.

Before using the robotic arm, please confirm that the zero-point posture of the robotic arm is consistent with the postures shown in Figure 2-8 and Figure 2-9. If the robotic arm has not moved to the position shown in the figure, please consult our company.

The robotic arm has been zero-point calibrated at the time of factory shipment, so there is no need for zero-point calibration in daily operations. However, zero-point calibration needs to be performed after the following situations occur.

  • Replaced the joint driver or robotic arm joint;

  • Reinstall the system or replace the controller;

  • After a severe collision.

The zero-point calibration positions of each axis of the robotic arm are shown in 2-10 and 2-11.

011.png

Chart 2-8 left arm zero position, right arm zero position

012.png

Chart 2-9 Left Arm Zero Position Calibration, Right Arm Zero Position Calibration